Series 9000 Total Hydrocarbon Analyzer

Series 9000 Total Hydrocarbon Analyzer
Partner: Baseline
Availability: EX Works
Qty:  
The Baseline® Series 9000 is the candidate of choice whenever accurate, reliable total hydrocarbon analysis is required. The Series 9000 analyzer provides unparalleled flexibility and offers continuous, fully automated gas analysis over a broad range of concentrations.

The 9000 has a dynamic range from less than 10 ppb on the low range version and up to 100% as methane on the high range version. The analyzer has a generous complement of analog, digital and logic output capabilities.

The analyzer is based on a flame ionization detector (FID) with FlowGuard electronic control that delivers a small portion of the sample gas to the detector flame. During the combustion process, organic or hydrocarbon-based gases in the sample are ionized then they are detected by the instrument and reported as a concentration.

The Series 9000 can be configured with internal components for single or multipoint analysis of non-condensing gas samples. The automatic calibration feature enhances the long-term analytical stability of the instrument. These features place the instrument well ahead of the competition in performance, automation, and configurability.


 

Applications  
The Series 9000 is designed to continuously monitor the total hydrocarbon content of non-condensing gases in a variety of applications, such as:
  • Beverage grade CO2 analysis
  • Scrubber & oxidizer efficiency
  • Carbon bed breakthrough detection
  • Contaminant analysis in pure/ultrapure inert gases
  • Well logging
  • Industrial hygiene & safety monitoring
  • Fenceline (perimeter) monitoring around industrial sites
  • LEL monitoring
     
 
Features  
  • Flame ionization detector.
  • 3U case, 19" (48.3cm) rack mountable.
  • Automatic calibration at user-defined intervals.
  • Internal, multipoint sampling option.
  • FlowGuard electronic control of fuel, air and sample.
  • Electronic back-pressure regulator with sample bypass system ensures fast response.
  • Discrete, multilevel concentration & fault alarms.
  • Analog output ranges programmable from 1ppm - 100% full scale.
  • Programmable relays for concentration alarms, events and diagnostics.
  • Automatic FID ignition, with automatic shut-off of sample, fuel and combustion air.
  • Remote operation via RS-232 and Ethernet.
  • Graphical display and easy to use menu system.
  • Optional 9000 Keeper software to monitor and control the instrument remotely.

Write a review

Your Name:


Your Review: Note: HTML is not translated!

Rating: Bad           Good

Enter the code in the box below:



Description

The Baseline® Series 9000 is the candidate of choice whenever accurate, reliable total hydrocarbon analysis is required. The Series 9000 analyzer provides unparalleled flexibility and offers continuous, fully automated gas analysis over a broad range of concentrations.

The 9000 has a dynamic range from less than 10 ppb on the low range version and up to 100% as methane on the high range version. The analyzer has a generous complement of analog, digital and logic output capabilities.

The analyzer is based on a flame ionization detector (FID) with FlowGuard electronic control that delivers a small portion of the sample gas to the detector flame. During the combustion process, organic or hydrocarbon-based gases in the sample are ionized then they are detected by the instrument and reported as a concentration.

The Series 9000 can be configured with internal components for single or multipoint analysis of non-condensing gas samples. The automatic calibration feature enhances the long-term analytical stability of the instrument. These features place the instrument well ahead of the competition in performance, automation, and configurability.


 

Applications  
The Series 9000 is designed to continuously monitor the total hydrocarbon content of non-condensing gases in a variety of applications, such as:
  • Beverage grade CO2 analysis
  • Scrubber & oxidizer efficiency
  • Carbon bed breakthrough detection
  • Contaminant analysis in pure/ultrapure inert gases
  • Well logging
  • Industrial hygiene & safety monitoring
  • Fenceline (perimeter) monitoring around industrial sites
  • LEL monitoring
     
 
Features  
  • Flame ionization detector.
  • 3U case, 19" (48.3cm) rack mountable.
  • Automatic calibration at user-defined intervals.
  • Internal, multipoint sampling option.
  • FlowGuard electronic control of fuel, air and sample.
  • Electronic back-pressure regulator with sample bypass system ensures fast response.
  • Discrete, multilevel concentration & fault alarms.
  • Analog output ranges programmable from 1ppm - 100% full scale.
  • Programmable relays for concentration alarms, events and diagnostics.
  • Automatic FID ignition, with automatic shut-off of sample, fuel and combustion air.
  • Remote operation via RS-232 and Ethernet.
  • Graphical display and easy to use menu system.
  • Optional 9000 Keeper software to monitor and control the instrument remotely.